Water Conservancy & Reservoirs
Reservoirs, canals and dams
Reservoirs, canals and dams rely on durable anti-seepage layers. We supply wide HDPE geomembrane, composite geomembrane and cement blanket for water infrastructure.
Key requirements
- Wide rolls for fewer joints in large reservoirs
- Composite membrane combines sealing with protection
- Cement blanket for channel and slope lining
Project conditions to confirm before purchase
- Pondage or canal purpose and the maximum head of water
- Drawdown range and how quickly the level changes
- Subgrade condition, slope angles and expected settlement
- Seepage-control requirement set by the design
Typical material build-up
- Prepared and compacted subgrade
- GCL or compacted clay liner where the design requires a secondary barrier
- HDPE geomembrane, or composite geomembrane where sealing and protection are combined
- Nonwoven geotextile protection layer and ballast or cover
- Cement blanket for channel and slope lining where concrete would be too slow or heavy
Typical sequence — the final build-up is confirmed by the project design, not by this page.
What to send for selection and quotation
- Plan and cross-sections, maximum water head and slope angles
- Subgrade condition and the seepage requirement
- Membrane grade or thickness if specified by the designer
- Quantity in m², and the destination port
Construction and testing points
- Anchor trenches at the crest and toes; allow for thermal movement during welding
- Trial welds and destructive seam tests per the specification
- Non-destructive testing of all seams as specified
- Protection layer and ballast placed before controlled filling
Material basis: HDPE geomembrane to GB/T 17643; composite geomembrane to GB/T 17642; cement blanket confirmed against its product data sheet. The build-up and CQA testing follow the project hydraulic and geotechnical design — no thickness is set here without the head, the slope and the subgrade condition.
Related technical notes
Material selection depends on the loading, the chemistry and the slope. Send the project conditions and we will confirm the membrane grade, protection layer and drainage detail.