Heap leach pads, tailings dams and ponds

Mining & Tailings

Mining operations need robust, chemical-resistant barriers for heap leach pads, tailings storage and process ponds. Our HDPE liners and geotextiles are built for aggressive service.

Key requirements

  • Chemical resistance checked against the specific leach solution (pH, composition, temperature)
  • High-friction textured liner for stacked slopes
  • Geotextile protection layers under and over the liner

Project conditions to confirm before purchase

  • Process or leach solution chemistry, including pH and temperature range
  • Type of facility: heap leach pad, tailings storage, process or storm pond
  • Design head, slope geometry and the deposition or stacking method
  • Design life and the chemical-resistance requirement for the liner

Typical material build-up

  1. Prepared and compacted subgrade
  2. GCL or compacted clay liner where a secondary barrier is required
  3. Chemical-resistant HDPE geomembrane — textured on stacked or steep slopes
  4. Nonwoven geotextile protection layer above and, where needed, below the liner
  5. Drainage layer or composite drainage net for solution collection

Typical sequence — the final build-up is confirmed by the project design, not by this page.

What to send for selection and quotation

  • Solution chemistry (pH, composition) and the operating temperature
  • Plan, cross-sections, slope angles and the design head
  • Membrane grade or thickness if specified by the designer
  • Quantity in m², and the destination port

Construction and testing points

  • Chemical compatibility of the selected grade checked against the leach solution before ordering
  • Trial welds and destructive seam tests per the specification
  • Non-destructive testing of all seams as specified
  • Protection layer and ballast placed to resist wind uplift and thermal movement

Material basis: HDPE geomembrane to GB/T 17643; protection geotextile to GB/T 17638. Chemical resistance depends on the actual leach solution (pH, composition, temperature) and is checked against the data sheet for the selected grade; the build-up follows the project design — no thickness is set here.

Material selection depends on the loading, the chemistry and the slope. Send the project conditions and we will confirm the membrane grade, protection layer and drainage detail.

Other applications